LATEST PUBLICATIONS
PN 2021-09
Gender Perspectives in E-livelihood and E-entrepreneurship
PN 2021-08
Promoting a More Innovative and Inclusive Society through ICT Development
SEARCA MGB 2021 2
Seed Guidebook: Scaling and Expanding for Effective Development the Experiences and Learning from the SEARCA Project ISARD
SEARCA RPCL 2021 6
Microbes for Sustainable Agriculture: Isolation and Identification of Beneficial Soil- and Plant-Associated Microorganisms

LATEST AV MATERIALS
PIDS WB 2021-0903
Annual Public Policy Conference Webinar 2: Ethical Business
PIDS WB 2021-0902
Opening Program and Annual Public Policy Conference Webinar 1: Resetting Capitalism
PIDS WB 2021-0901
19th Development Policy Research Month Kick-Off Forum
PIDS WB 2021-0702
Local Governments' PDP and SDG Localization Efforts as Contribution to National Development
Publication Detail
JA 2018 036: Operational Impact of RES Penetration on a Remote Diesel-Powered System in West Papua, Indonesia

When a new power source connects to the distribution or transmission grid, an assessment of its impact is necessary. Technical studies must assess the possible effects of a proposed expansion, reinforcement or modification to evaluate the possible incidents that may occur. Typically, the calculations or analyses done are load flow, short-circuit, and transient stability. The possible renewable energy (RE) sources are determined first. The details of the existing electrical system, including the specifications for the elements used, are obtained and logical assumptions are utilized for those that are not known. The load flow analysis in the considered case revealed that the RE presence reduces diesel generation. The 119 kW PV array and the 54 kW tidal turbine displace most diesel generation: 22% of Gen 4 and 21.8% of Gen 5. The diesel-solar system brought the diesel generation down by 20.05% of Gen 4 and 20% of Gen 5. The diesel-tidal combination lessened the diesel generation by 1.92% of Gen 4 and 1.83% of Gen 5. Short-circuit analysis alerts indicating the operating percentages of the circuit breakers that are beyond their interrupting ratings are presented. The transient stability analysis depicts that RE sources affect the existing system and appear to be putting in more stress. The studied systems are not transient-stable based on the results. While it is relatively simple to plan to put up renewables in remote island systems, there are many factors to consider such as the possible impacts of the RE sources

Silliman University
Authors Keywords
Tuballa, Maria Lorena L. (Silliman University): Abundo, Michael Lochinvar S. ; electrical grid; renewable energy; transient stability; diesel generation; tidal turbine;
Download PDF Number of Downloads
Published in 2018 and available for Downloaded 14 times since March 02, 2021
×
Please let us know your reason for downloading this publication. May we also ask you to provide additional information that will help us serve you better? Rest assured that your answers will not be shared with any outside parties. It will take you only two minutes to complete the survey. Thank you.


To use as reference:
If others, (Please specify):
Name: (optional)
Email: (required, but will not display)
Age:
Gender:
If Prefer to self-describe, please specify:
Level of Education:
Occupation:
If employed either part-time or full-time, name of office:
If others, (Please specify):
Would you like to receive the SERP-P UPDATES e-newsletter? Yes No
Use the space below if you have any comment about this publication or SERP-P knowledge resources in general.